Improving Radiographers’ Knowledge Through the Dissemination of Research Findings on Brain CT Examination Techniques for Emergency Patients to Overcome Motion Artifacts
Authors
Abstract
This community service activity aimed to improve radiographers’ knowledge and understanding of how to manage motion artifacts in computed tomography (CT) examinations and how to apply a fast-scan protocol to emergency patients. Motion artifacts are image distortions caused by patient movement during data acquisition, and they can reduce diagnostic image quality. They are a particular concern in emergency patients, especially those with head trauma, reduced consciousness, or difficulty maintaining position during the examination. The activity was designed as an educational intervention with a one-group pre-test–post-test evaluation. It consisted of a dissemination session on research findings concerning brain CT examination techniques, followed by an assessment of participants’ knowledge using a 15-item questionnaire covering the concept of motion artifacts, their causes, preventive measures, radiographer–patient communication, and the fast-scan protocol for head CT. Eleven radiographers at the Radiology Installation of RSI Siti Rahmah Padang took part. The mean proportion of correct answers was 37.6% in the pre-test and 100% in the post-test, a descriptive increase of 62.4 percentage points. These results indicate that the dissemination session had a positive effect on participants’ knowledge of motion artifact prevention and of the importance of applying a fast-scan protocol in emergency patients. The activity is expected to support radiographers’ competence in optimizing image quality, examination efficiency, and patient safety. Further evaluation through practice observation and image quality assessment is needed to determine whether this knowledge is applied in radiology services.
Keywords
References
- Expert Panel on Neurological Imaging, Shih RY, Burns J, Ajam AA, Broder JS, Chakraborty S, et al. ACR Appropriateness Criteria® head trauma: 2021 update. J Am Coll Radiol. 2021;18(5S):S13–S36. doi: 10.1016/j.jacr.2021.01.006
- Ho ML, Blumfield E, Lasiecka ZM, Kam A, Nagaraj UD, Narayanan S, et al. ACR–ASNR–SPR practice parameter for the performance of computed tomography (CT) of the head. AJNR Am J Neuroradiol. 2026;47(4):853–862. doi: 10.3174/ajnr.A9106
- Alzain AF, Elhussein N, Fadulelmulla IA, Ahmed AM, Elbashir ME, Elamin BA. Common computed tomography artifact: source and avoidance. Egypt J Radiol Nucl Med. 2021;52:151. doi: 10.1186/s43055-021-00530-0
Show 11 more references
- Su B, Wen Y, Liu Y, et al. A deep learning method for eliminating head motion artifacts in computed tomography. Med Phys. 2022;49(1):411–419. doi: 10.1002/mp.15354
- Chen Z, Li Q, Wu D. Estimate and compensate head motion in non-contrast head CT scans using partial angle reconstruction and deep learning. Med Phys. 2024;51(5):3309–3321. doi: 10.1002/mp.17047
- Gupta K, Colvert B, Chen Z, Contijoch F. DiFiR-CT: distance field representation to resolve motion artifacts in computed tomography. Med Phys. 2023;50(3):1349–1366. doi: 10.1002/mp.16157
- Amirian M, Montoya-Zegarra JA, Herzig I, Eggenberger Hotz P, Lichtensteiger L, Morf M, et al. Mitigation of motion-induced artifacts in cone beam computed tomography using deep convolutional neural networks. Med Phys. 2023;50(10):6228–6242. doi: 10.1002/mp.16405
- Serra D, Neep MJ, Ryan E. Multi-centre digital radiography reject analysis for different clinical room use types: the establishment of local reject reference levels for public hospital departments. J Med Radiat Sci. 2024;71(3):412–420. doi: 10.1002/jmrs.796
- Alshamrani KM, Alkenawi AA, Kaifi RE, Alhulil KA, Munshi WM, Alqurayqiri AF, et al. The barriers, motives, perceptions, and attitudes toward research among radiology practitioners and interns in Saudi Arabia: a cross-sectional study. Front Med (Lausanne). 2023;10:1266285. doi: 10.3389/fmed.2023.1266285
- Hunter JG, Bera K, Ciancibello L, Bukhari SMA, Sposato J, Ansari Gilani K, et al. Real-world impact of high-pitch helical CT on radiation exposure and image quality in infants being evaluated for cardiothoracic pathologies. Pediatr Radiol. 2025;55(1):151–158. doi: 10.1007/s00247-024-06115-z
- Sugandi ES, Suharlim E, Kusmiati E, Hayati IM. Peningkatan pemahaman radiografer tentang komunikasi efektif melalui kegiatan penyuluhan di Rumah Sakit XYZ. Jurnal Pengabdian Masyarakat dan Penelitian Terapan. 2025;3(4):159–164. doi: 10.38035/jpmpt.v3i4.1421
- Mayani AN, Adi EP. Peningkatan pengetahuan mahasiswa sebagai calon radiografer tentang petugas proteksi radiasi. JMM (Jurnal Masyarakat Mandiri). 2021;5(5):2918–2924. doi: 10.31764/jmm.v5i5.6024
- Primasyukra MA, Ulina S, Adiansyah, Galang T, Gemasih I. Sosialisasi dan pelatihan kalibrasi pesawat sinar-X radiografi umum sebagai upaya peningkatan keselamatan radiasi di Instalasi Radiologi RSU Elpi Al Azis Rantau Prapat. Jurnal Abdimas Mutiara. 2026;7(2):7–12. doi: 10.51544/jam.v7i2.6288
- Harnanto R, Adi K, Dartini D, Wibowo GM, Rasyid R. Pengembangan model aplikasi pelatihan pengendalian mutu computed tomography (CT) berbasis American College of Radiology (ACR) phantom terintegrasi web. Jurnal Imejing Diagnostik (JImeD). 2025;11(2):58–63. doi: 10.31983/jimed.v11i2.13457
Copyright (c) 2026 Livia Ade Nansih, Sagita Yudha, Nerifa Dewilza, Hanna Glensia Simamora, Vauzia Ramadhani, Nilam Putri Effendi · CC BY-SA 4.0