Optimization of Image Quality Parameters of Cranium Examination to Prevent Radiograph Repetition
DOI:
https://doi.org/10.62872/o.v3i1.487Keywords:
Cranium, Intensity , Contrast, mAs, OptimizationAbstract
Cranium radiography technique is a technique of depicting the cranium using X-rays to obtain radiographs to help establish a diagnosis. In cranium examination, high sharpness and detail are required so that the information obtained on the radiograph is clearly visible. On the other hand, exposure factors, namely tube voltage, tube current, time, and the Focus Film Distance (FFD) factor as well as the width of the radiation field are very important so that the desired object is visualized correctly and well and to avoid repeat radiographs. The purpose of this study is to find a reference for optimizing the mAs exposure factor in Cranium Examination.to prevent repeat radiographs.This research method is quantitative experiment. The research sample in the form of a cranium phantom was exposed three times with variations of mAs 16, 20, and 25 at a constant voltage of 60 kV to obtain optimal image results. Based on histogram analysis, mAs 16 produces a more even distribution of intensity values and more optimal contrast compared to mAs 20 and 25. Therefore, mAs 16 is the most efficient variation for AP projection cranium examination because it is able to produce good diagnostic image quality with a low radiation dose.
References
Akhadi, M. (2020). X-rays Answer Health Problems. deepublish.
Amroji, A., Pratiwi, R. F., & Andriana, A. (2019). Perbandingan Rata-Rata Densitas Pada Hasil Foto Thorax Proyeksi Antero Posterior (AP) Supine dan Duduk Tegak 1. Jurnal Radiografer Indonesia, 1–8.
Aulia, T. (2021). Perbandingan Kualitas Citra Radiografi Thorax Proyeksi Posteroanterior (Pa) Pada Variasi Focus Film Distance. 1–79.
Balingger, philip w. (2019). Merril’s Atlas Of Radiographic Positions dan Radiologi Procedures.
Carroll, Q. B. (2019). Digital Radiography in Practice.
Castilho, P. R., Schelin, H., Denyak, V., Mello, R., Legnani, A., & Paschuk, S. (2023). Assessment of image quality in digital radiology using the CDRAD contrast-detail phantom in pediatrics. 9(3), 11–16.
Dewilza, N., & Yudha, S. (2023). Dasar-Dasar CT-Scan. Deepublish.
Faradina Pratiwi, R., Sundari Pulungan, E., & Andini, D. (2023). Pengaruh Faktor Eksposi Terhadap Kualitas Citra Radiografi Pada Pemeriksaan Thorax. JRI (Jurnal Radiografer Indonesia), 6(1), 38–41. https://doi.org/10.55451/jri.v6i1.173
Irsal, M., & Winarno, G. (2020). Pengaruh Parameter Milliampere-Second (mAs) terhadap Kualitas Citra Dan Dosis Radiasi Pada Pemeriksaan CT scan Kepala Pediatrik. Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat, 17(1), 1. https://doi.org/10.20527/flux.v17i1.7085
Labania, H. M., P. Rindayani, Kasman, Abd. Rahman, & S. Ulum. (2021). Analisis Kontras Digital Radiography Dengan Menggunakan ImageJ. Gravitasi, 20(1), 10–18. https://doi.org/10.22487/gravitasi.v20i1.15521
Mufida, W., Utami, A. P., & Dewi, S. N. (2020). Pembuatan Phantom Radiologi Berbahan Dasar Kayu Lokal sebagai Pengganti Tulang Manusia. Jurnal Imaging Diagnostik, 6, 7–10.
Nansih, L. A. (2022). FACTORS OF FAILURE TO REPEAT X-RAY PHOTOS ON COMPUTED RADIOGRAPHY IN RADIOLOGY UNIT dr. REKSODIWIRYO HOSPITAL PADANG. Jurnal Ilmu Dan Teknologi Kesehatan STIKES Widya Husada, 13(1), 27–32.
Oktavia Puspita Sari. (2023). Jurnal Kesehatan Saintika Meditory. 30–34.
Prayoga, A. N., Suraningsih, N., & Puspita, M. I. (2022). the Effect of Exposure Factors on Radiographic Image Quality on Thorax Phantom With Pa Projection. Jurnal Ilmu Dan Teknologi Kesehatan, 13(1), 22–26. https://doi.org/10.33666/jitk.v13i1.425
Priyono, S., Anam, C., & Wahyu Setia Budi, D. (2020). Pengaruh Rasio Grid Terhadap Kualitas Radiograf Fantom Kepala. Berkala Fisika, 23(1), 10–16.
Sagita Yudha M.Tr.Kes., S. S., Oktavia Puspita Sari S.Si., M.Kes., A. R., Santa Mareta SKM., M.Kes., A. M. R., Nerifa Dewilza S.Si., M.Tr.Kes., A. M. R., Cicillia Artitin M.Biomed, S. S., Livia Ade Nansih M.Biomed, S. S. T., Wahdini Hanifah M.Tr.ID, S. T. K., & Chairun Nisa M.Si., S. P. (2025). Radiofotografi: Dasar dan Aplikasinya. In S. P. Ahmad Fauzy Pratama (Ed.), Bukuloka Literasi Bangsa. Bukuloka Literasi Bangsa.
Sudarsih, K., Rosidah, S., & Budiwati, T. (2019). PELAKSANAAN PROGRAM KENDALI MUTU PESAWAT SINAR-X DI INSTALASI RADIOLOGI RSI SULTAN AGUNG SEMARANG. 129(129), 2–3.
Sugiyono. (2019). Metodologi Penelitian Kuantitatif & Kualitatif dan R&D. Alfabeta.
Takagi, S., Yaegashi, T., & Ishikawa, M. (2019). Relationship Between Tube Voltage and Physical Image Quality of Pulmonary Nodules on Chest Radiographs Obtained Using the Bone-Suppression Technique. Academic Radiology, 26(7), e174–e179. https://doi.org/10.1016/j.acra.2018.08.017
Yudha, S., Dewilza, N., Sari, O. P., & Nisa, C. (2025). KILOVOLT VARIATION AND DIGITAL IMAGE CONTRAST : PHANTOM STUDY COMPARISON. 18(1), 50–55.
Yudha, S., Kes, M. T., Dewilza, N., Rad, A. M., & Kes, M. T. (2023). Radiografi Digital. Deepublish
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Chairun Nisa, Sagita Yudha, Wahdini Hanifah, Livia Ade Nansih, Ohana Yanisa Ibrahim (Author)

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.







