Comparison of Digital Image Quality of Postero-Anterior (PA) Projection Thoracic Radiography at Various Film Distance Focuses
DOI:
https://doi.org/10.62872/o.v3i1.486Keywords:
Focus Film Distance, Radiography Image Quality, ThoraxAbstract
Focus film distance (FFD) is the standard distance between the x-ray emission point in the x-ray tube (focal spot) and the image receptor. Based on the author's experience during observations in more than one hospital, where almost all observation places, researchers noticed that officers rarely see the details of the FFD, with an average of 180 cm being used in PA projection thorax examinations. The purpose of this study was to compare the quality of radiographic images in PA projection thorax examinations and to determine which FFD is optimal in the FFD variations of 117 cm, 150 cm, 183 cm in PA projection thorax examinations. The type of research used in this study is a quantitative experimental study through literature studies, observations and questionnaires, in order to achieve the objectives of the study. This study was conducted at the H. Hanafie Muara Bungo Regional Hospital in June. The sample in this study amounted to 5 people. Data collection was carried out by questionnaire, the data obtained was then processed using the SPSS application. The results of this study indicate that in the use of FFD variations there are differences in image quality. The results of SPSS calculations show that the significance value is <0.05, which means that H0 is rejected and Ha is accepted. FFD 150 cm is the optimal distance in producing quality radiographic images in postero-anterior projection thorax examinations.
References
Adela, M. (2023). Pengaruh Variasi Focus Film Distance (FFD) Pada Pemeriksaan Thorax Proyeksi Postero Anterior (PA)Terhadap Nilai Kulaitas Citra. Baiturrahmah.
Amroji, A., Pratiwi, R. F., & Andriana, A. (2019). Perbandingan Rata-Rata Densitas Pada Hasil Foto Thorax Proyeksi Antero Posterior (AP) Supine dan Duduk Tegak 1. Jurnal Radiografer Indonesia, 1–8.
Aulia, T. (2021). Perbandingan Kualitas Citra Radiografi Thorax Proyeksi Posteroanterior (Pa) Pada Variasi Focus Film Distance. 1–79.
Faradina Pratiwi, R., Sundari Pulungan, E., & Andini, D. (2023). Pengaruh Faktor Eksposi Terhadap Kualitas Citra Radiografi Pada Pemeriksaan Thorax. JRI (Jurnal Radiografer Indonesia), 6(1), 38–41. https://doi.org/10.55451/jri.v6i1.173
Fitriani, Zelviani, S., & Sahara. (2019). Pengaruh Tegangan Tabung (kV) Pada Pemeriksaan Thorax Terhadap Kualitas Citra Radiografi Di BBKPMM. Concept and Communication, null(23), 301–316.
Imam Suyudi. (2024). PENGARUH VARIASI FOCUS FILM DISTANCE (FFD) TERHADAP CARDIOTHORACIC RATIO (CTR) DAN SIGNAL-TO-NOISE RATIO (SNR). 15, 123–129. https://doi.org/10.38165/jk.v15i2.4
Kuwahara, C., Aoki, T., Oda, N., Kawabata, J., Sugimoto, K., Kobayashi, M., Fujii, M., & Korogi, Y. (2019). Optimal beam quality for chest flat panel detector system: realistic phantom study. European Radiology, 29(9), 4538–4543. https://doi.org/10.1007/s00330-019-5998-1
Labania, H. M., P. Rindayani, Kasman, Abd. Rahman, & S. Ulum. (2021). Analisis Kontras Digital Radiography Dengan Menggunakan ImageJ. Gravitasi, 20(1), 10–18. https://doi.org/10.22487/gravitasi.v20i1.15521
Mayani, A. N., & Muflihatun. (2017). Pengaruh Variasi Focus Film Distance (FFD) Terhadap Hasil Presisi Pengukuran Cardiothoracic Ratio (CTR). Prosiding Pertemuan Dan Presentasi Ilmiah Penelitian Dasar Ilmu Pengetahuan Dan Teknologi Nuklir, November, 59–64.
Nansih, L. A. (2022). FACTORS OF FAILURE TO REPEAT X-RAY PHOTOS ON COMPUTED RADIOGRAPHY IN RADIOLOGY UNIT dr. REKSODIWIRYO HOSPITAL PADANG. Jurnal Ilmu Dan Teknologi Kesehatan STIKES Widya Husada, 13(1), 27–32.
Notoadmojo. (2020). Metodologi penelitian. rineka cipta.
Nugraha M., S. (2020). Analisa Focus FIlm Distance Optimal Pada Pemeriksaan Thorax PA Terhadap Hasil Ukur Cardiothoracic Ratio Yang Akurat. Jurusan Teknik Radiodiagnostik dan Radioterapi.
Oktavia Puspita Sari, Dipl.Rad., S.Si., M. K., Santa Mareta, A.Md.Rad., SKM., M. K., Livia Ade Nansih, A.Md.Rad., S.ST., M. B., Cicilia Artitin, A.Md.Rad., S.Si., M. B., Sagita Yudha, A.Md.Rad., S.Si., M. T. K., Nerifa Dewilza, A.Md.Rad., S.Si., M. T. K., & Wahdini Hanifah, S.Tr.Kes., M. T. I. (2024). Teknik Radiografi II. Bukuloka Literasi Bangsa.
Prayoga, A. N., Suraningsih, N., & Puspita, M. I. (2022). the Effect of Exposure Factors on Radiographic Image Quality on Thorax Phantom With Pa Projection. Jurnal Ilmu Dan Teknologi Kesehatan, 13(1), 22–26. https://doi.org/10.33666/jitk.v13i1.425
Rahmadianti, Y., Yudha, S., Dewilza, N., Nansih, L. A., & Ramadanti, T. (2023). Lead apron leak test at the Padang Reksodiwiryo Army Hospital ’ s radiology installation. VIII(1), 5–10.
Sari, O. P., Dasril, D. N., Nisa, C., & Almaiza, A. (2020). Pengujian Kebocoran Apron Tahun 2019. Jurnal Imejing Diagnostik (JImeD), 6(2), 65–68. https://doi.org/10.31983/jimed.v6i2.5826
Sugiyono. (2019). Metodologi Penelitian Kuantitatif & Kualitatif dan R&D. Alfabeta.
Sumariyah, S., Umiati, N. K., Fisika, S. S.-B., & 2008, undefined. (2014). Variasi Nilai Eksposi Aturan 15 Persen pada Radiografi Menggunakan Imaging Plate untuk Mendapatkan Kontras Tertinggi. Eprints.Undip.Ac.Id, 3(4), 251–256.
Takagi, S., Yaegashi, T., & Ishikawa, M. (2019). Relationship Between Tube Voltage and Physical Image Quality of Pulmonary Nodules on Chest Radiographs Obtained Using the Bone-Suppression Technique. Academic Radiology, 26(7), e174–e179. https://doi.org/10.1016/j.acra.2018.08.017
Tjuanda, Y. (2021). Quality Analysis Of Thorax Radiography Images In Postero Anterior Projection ( PA ) With Focus Film Distance ( FFD ) Variations In The Radiology Installation Of Sundari General Hospital. 2(2), 653–660.
Yudha, S., Dewilza, N., Sari, O. P., & Nisa, C. (2025). Kilovolt Variation And Digital Image Contrast : Phantom Study Comparison. 18(1), 50–55.
Yudha, S., Kes, M. T., Dewilza, N., Rad, A. M., & Kes, M. T. (2023). Radiografi Digital. Deepublish.
YUSRIWAN TJUANDA. (2021). Analisa Kualitas Citra Radiografi Thorax Proyeksi Postero Anterior (Pa) Dengan Variasi Focus Film Distance (Ffd) Di Instalasi Radiologi Rumah Sakit Umum Sundari. 5(3), 213–220.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Sagita Yudha, Noviardi Prima Putra, Nerifa Dewilza, Wahdini Hanifah , Alamsyah Alamsyah (Author)

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.